2 Cores Xlpe Insulated Power Cable

Xlpe Insulated Power Cable
2-core power xlpe insulated power cable are usually used in power transmission and distribution systems. The 2-core XLPE cable is called IEC60502 CU / XLPE / PVC 0.6 / 1KV. Round conductors are suitable for sizes below 16mm², and shaped conductors are suitable for sizes above 35mm² (including 35mm²). We can also provide XLPE insulated two-core power cables according to BS7889.
The two-core cable is only composed of live wire and neutral wire and is suitable for “Class II equipment” (no grounding).
Description Of 2 Cores Power Cable (XLPE Insulated)
- Rated Temperature: 90℃
- Rated Voltage: 600/1000V
- Reference Standard: IEC60502
- Conductor: Shaped and circular stranded copper conductors
- Insulated: Insulated with cross-link polyethylene compound
- PVC bedded
- Flame retardant PVC sheathed overall
2-core power xlpe insulated power cable Characteristics
Cross-sectional Area (mm²) | No.&diameter of wire (N/mm) | Average overall diameter (mm) | Reference weight (kg/km) | Conductor Resistance (Ω/km) |
20ºC Max | ||||
2×1.5 | 1/1.38 | 12 | 180 | 12.1 |
2×2.5 | 1/1.76 | 12.8 | 217 | 7.41 |
2×4.0 | 7/0.85 | 14.4 | 286 | 4.61 |
2×6.0 | 7/1.04 | 15.4 | 349 | 3.08 |
2×10 | 7/1.35 | 17.4 | 482 | 1.83 |
2×16 | 7/1.7 | 19.4 | 652 | 1.15 |
2×25 | 10/1.83 | 17.2 | 663 | 0.727 |
2×35 | 14/1.83 | 18.8 | 868 | 0.524 |
2×50 | 19/1.83 | 21.1 | 1153 | 0.387 |
2×70 | 27/1.83 | 23.8 | 1568 | 0.268 |
2×95 | 37/1.83 | 26.1 | 2067 | 0.193 |
2×120 | 30/2.32 | 28.8 | 2613 | 0.153 |
2×150 | 37/2.32 | 32.1 | 3185 | 0.124 |
2×185 | 37/2.52 | 35 | 3860 | 0.0991 |
2×240 | 48/2.52 | 38.9 | 4930 | 0.0754 |
2×300 | 61/2.52 | 43.3 | 6166 | 0.0601 |
2×400 | 61/2.95 | 48.5 | 8330 | 0.047 |
Use Function
XLPE/PVC insulated wire covering series of wire products, its working temperature varies according to different insulating materials, mainly 70 degrees and 90 degrees.
According to the conductor type, including solid conductor PVC/XL. PE insulated wire, vertical PVC/XL PE insulated wire, flexible PVC/XLPE insulated wire, different colors.
According to its shape, including flat line, round line, etc., the color is different.
Meet the number of cores, including single-core wires and multi-core wires of different colors.
The long-term working conductor allows the maximum operating temperature of 90oC. In short circuit (long-term maximum value does not exceed 5 seconds). The maximum temperature of the conductor does not exceed 250.
The impedance of the conductor meets the requirements of GB/T3956-1997.
When laying, the ambient temperature should not be lower than 0. Otherwise, it should be preheated. There is no horizontal fall restriction when laying cables. The minimum bending radius of the three-core cable should be 12 times the outer diameter of the cable.
Partial discharge test: The discharge capacity of the cable should not exceed 10pC and less than 1.73Uo.