Low Voltage Armoured Power Cable
Home » Armoured Cable » Low Voltage Armoured Power Cable
Low Voltage Armoured Power Cable
HOLDONE, a renowned manufacturer, specialises in producing high quality Low Voltage Steel Ribbon Power Cables that provide a solid guarantee of energy transmission in a wide range of industries. These cables are an integral part of modern power systems and are used in a wide range of applications such as construction, industry, energy distribution, and outdoor applications. The core features of our Low Voltage Steel Ribbon Power Cables are their superior design and high quality materials. The copper or aluminium conductors inside the cable ensure efficient and stable current transmission. And the special cross-linked polyethylene (XLPE) or polyvinyl chloride (PVC) insulation not only prevents current leakage, but also effectively resists the effects of humidity and other environmental factors.
Low Voltage Armoured Power Cable Parameter
| Nominal Conductor Area | No. and Diameter of Wires | Nominal Diameter of Conductor | Maximum Conductor | Nominal Weight per km of | 
| (mm2) | (no./mm) | (mm) | (0/km) | Conductor (kg/km) | 
| 1 | 7 / 0.43 | 1.29 | 18.1 | 9.2 | 
| 1.5 | 7 / 0.53 | 1.59 | 12.1 | 14 | 
| 2.5 | 7 / 0.67 | 2.01 | 7.41 | 22.4 | 
| 4 | 7 / 0.85 | 2.55 | 4.61 | 36.1 | 
| 6 | 7 / 1.04 | 3.12 | 3.08 | 54 | 
| 10 | 7 / 1.35 | 4.05 | 1.83 | 90.8 | 
| 16 | 7 / 1.70 | 4.69 | 1.15 | 145 | 
| 25 | 7 / 2.14 | 5.9 | 0.727 | 229 | 
| 35 | 7 / 2.52 | 6.95 | 0.524 | 317 | 
| 50 | 19 / 1.78 | 8.4 | 0.387 | 429 | 
| 70 | 19 / 2.14 | 10.1 | 0.268 | 620 | 
| 95 | 19 / 2.52 | 11.9 | 0.193 | 860 | 
| 120 | 37 / 2.03 | 13.5 | 0.153 | 1086 | 
| 150 | 37 / 2.25 | 14.9 | 0.124 | 1334 | 
| 185 | 37 / 2.52 | 16.9 | 0.0991 | 1673 | 
| 240 | 61 / 2.25 | 19.2 | 0.0754 | 2199 | 
| 300 | 61 / 2.52 | 21.5 | 0.0601 | 2759 | 
| 400 | 61 / 2.85 | 24.3 | 0.047 | 3528 | 
| 500 | 61 / 3.20 | 27.3 | 0.0366 | 4448 | 
| 630 | 127 / 2.52 | 32.76 | 0.0283 | 5744 | 
| 800 | 127 / 2.85 | 37.05 | 0.0221 | 7346 | 
| 1000 | 127 / 3.20 | 41.6 | 0.0176 | 9260 | 
| No. Cores | Conduct or Cross | Cable Cross Section Area (mm²) | Actual Armour Cross Section Area (mm²) | Overall Diameter (mm) | Gland | Cleat Size | 
| 2 | 1.5 | 114.93 | 15 | 12.1 | 20S | 5 | 
| 2 | 2.5 | 145.19 | 17 | 13.6 | 20S | 6 | 
| 2 | 4 | 169.63 | 19 | 14.7 | 20S | 6 | 
| 2 | 6 | 198.46 | 22 | 15.9 | 20 | 7 | 
| 2 | 10 | 254.34 | 26 | 18 | 20 | 8 | 
| 2 | 16 | 326.69 | 42 | 20.4 | 25 | 9 | 
| 2 | 25 | 455.94 | 42 | 24.1 | 25 | 10 | 
| 2 | 35 | 426.17 | 60 | 23.3 | 25 | 10 | 
| 2 | 50 | 522.53 | 68 | 25.8 | 32 | 11 | 
| 2 | 70 | 660.19 | 80 | 29 | 32 | 12 | 
| 2 | 95 | 860.05 | 113 | 33.1 | 40 | 14 | 
| 2 | 120 | 1023.02 | 125 | 36.1 | 40 | 16 | 
| 2 | 150 | 1212.42 | 138 | 39.3 | 40 | 18 | 
| 2 | 185 | 1568.5 | 191 | 44.7 | 50 | 20 | 
| 2 | 240 | 1884.79 | 215 | 49 | 50 | T9 | 
| 2 | 300 | 2246.87 | 235 | 53.5 | 63 | T9 | 
| 2 | 400 | 2732.59 | 265 | 59 | 63 | T10 | 
| No. Cores | Conduct or Cross Sec- tion Area (mm²) | Cable Cross Section Area (mm²) | Actual Armour Cross Section Area (mm²) | Overall Diameter (mm) | 
| 3 | 1.5 | 124.63 | 16 | 12.6 | 
| 3 | 2.5 | 156.07 | 19 | 14.1 | 
| 3 | 4 | 183.76 | 20 | 15.3 | 
| 3 | 6 | 216.31 | 23 | 16.6 | 
| 3 | 10 | 298.5 | 39 | 19.5 | 
| 3 | 16 | 366.25 | 45 | 21.6 | 
| 3 | 25 | 510.45 | 62 | 25.5 | 
| 3 | 35 | 615.44 | 68 | 28 | 
| 3 | 50 | 637.62 | 78 | 28.5 | 
| 3 | 70 | 813.92 | 90 | 32.2 | 
| 3 | 95 | 1074.67 | 128 | 37 | 
| 3 | 120 | 1281.25 | 141 | 40.4 | 
| 3 | 150 | 1625.15 | 201 | 45.5 | 
| 3 | 185 | 1946.83 | 220 | 49.8 | 
| 3 | 240 | 2383.27 | 250 | 55.1 | 
| 3 | 300 | 2844.87 | 269 | 60.2 | 
| 3 | 400 | 3481.91 | 304 | 66.6 | 
| No. Cores | Conduct or Cross Section Area (mm²) | Cable Cross Section Area (mm²) | Actual Armour Cross Section Area (mm²) | Overall Diameter (mm) | Gland | Cleat Size | 
| 4 | 1.5 | 143.07 | 17 | 13.5 | 20s | 6 | 
| 4 | 2.5 | 176.63 | 20 | 15 | 20s | 6 | 
| 4 | 4 | 211.13 | 23 | 16.4 | 20 | 7 | 
| 4 | 6 | 274.51 | 36 | 18.7 | 20 | 8 | 
| 4 | 10 | 349.49 | 43 | 21.1 | 25 | 9 | 
| 4 | 16 | 411.66 | 49 | 22.9 | 25 | 11 | 
| 4 | 25 | 597.98 | 70 | 27.6 | 32 | 12 | 
| 4 | 35 | 725.47 | 78 | 30.4 | 32 | 12 | 
| 4 | 50 | 803.84 | 90 | 32 | 32 | 14 | 
| 4 | 70 | 1115.71 | 131 | 37.7 | 40 | 16 | 
| 4 | 95 | 1365.03 | 147 | 41.7 | 50 | 18 | 
| 4 | 120 | 1741.45 | 206 | 47.1 | 50 | 20 | 
| 4 | 150 | 2073.94 | 230 | 51.4 | 50 | TC9 | 
| 4 | 185 | 2514.79 | 255 | 56.6 | 63 | TC10 | 
| 4 | 240 | 3115.75 | 289 | 63 | 63 | TC11 | 
| 4 | 300 | 3715.75 | 319 | 68.8 | 75 | TC12 | 
| 4 | 400 | 4788.19 | 452 | 78.1 | 75 | TC14 | 
| No. Cores | Conduct or Cross Section Area (mm²) | Stranding mm | Approx weight kg/km | Approx overall diameter | Gland size mm | Single cleat | Nom. Max. DC-resist conductor 20oC ohm/km | Current rating laid direct amp | 
| 5 | 1.5 | 7/0.53 | 395 | 13.72 | 20s | 0.6 | 12.1 | 32 | 
| 5 | 2.5 | 7/0.67 | 497 | 15.46 | 20s | 0.6 | 7.41 | 42 | 
| 5 | 4 | 7/0.85 | 674 | 17.38 | 20 | 0.7 | 4.61 | 55 | 
| 5 | 6 | 7/1.04 | 868 | 19.05 | 20 | 0.8 | 3.08 | 69 | 
| 5 | 10 | 7/1.35 | 1197 | 22.06 | 25 | 0.9 | 1.83 | 92 | 
| 5 | 16 | 7/1.70 | 1780 | 24.14 | 25 | 1.1 | 1.15 | 119 | 
| 5 | 25 | 7/2.14 | 2435 | 28.4 | 32 | 1.2 | 0.727 | 152 | 
| 5 | 35 | 7/2.52 | 2800 | 33 | 40 | 1.4 | 0.524 | 182 | 
| 5 | 50 | 19/1.78 | 3850 | 38 | 40 | 1.6 | 0.387 | 217 | 
| 5 | 70 | 19/2.14 | 5100 | 42.9 | 50s | 1.8 | 0.268 | 266 | 
| 5 | 95 | 19/2.52 | 7700 | 52.1 | 50 | TC9 | 0.193 | 319 | 
 
 
 