Submersible Oil Pump Cable

Submersible Oil Pump Cable

HOLDONE is a professional manufacturer dedicated to producing high-quality Submersible Oil Pump Cable, which is a key component used for transmitting electricity in submersible environments such as oil wells. Made of high quality materials and advanced technology, it has excellent corrosion resistance and durability, and can operate stably for a long time in the harsh oil field environment. Its special waterproof design prevents water from penetrating into the cable, ensuring safe and reliable power transmission. HOLDONE also offers customised options in a wide range of sizes and lengths to meet the needs of different oil wells. Their products have passed strict quality control and certification systems to ensure that users receive reliable support and service during purchase and use.

Submersible Oil Pump Cable Parameter

Conductor Specification

EPDM Insulation

LEAD Sheath

Finished Size ≤ mm

Calculated Weight kg/m

AWG

Area m㎡

Outer Diameter mm

Thickness mm

Outer Diameter mm

Thickness mm

Outer Diameter mm

Thickness mm

Width mm

 

6

13

4.12

1.7

7.52

0.76

9.12

13.14

35.72

1.7

4

20

5.19

1.7

8.59

0.76

10.19

14.21

35.93

2.1

2

33

6.54

1.7

9.94

0.76

11.54

15.56

40.00

2.6

1

42

7.35

1.7

10.75

0.76

12.35

16.37

42.41

3.0

Conductor Specification

EPDM Insulation

LEAD Sheath

Finished Size ≤mm

Calculated Weight kg/m

AWG

Area m㎡

Outer Diameter mm

Thickness mm

Outer Diameter mm

Thickness mm

Outer Diameter mm

Thickness mm

Width mm

 

6

13

4.12

1.9

7.92

0.76

9.52

12.54

34.00

1.85

4

20

5.19

1.9

8.99

0.76

10.59

14.61

37.13

2.23

2

33

6.54

1.9

10.34

0.76

11.94

15.96

41.00

2.77

1

42

7.35

1.9

11.15

0.76

14.75

16.80

43.60

3.14

Conductor Specification

EPDM Insulation

LEAD Sheath

EPDM Shealth

Finished Size  mm

Calculated Weight kg/m

AWG

Area m㎡

Outer Diameter mm

Thickness mm

Outer Diameter mm

Thickness mm

Outer Diameter mm

Thickness mm

Outer Diameter mm

 

 

6

13

4.12

1.7

7.92

0.75

9.12

1.52

23.71

28.61

2.03

4

20

5.19

1.7

8.99

0.75

10.19

1.52

26.01

30.92

2.44

2

33

6.54

1.7

10.34

0.75

11.54

1.52

28.92

33.82

3.02

1

42

7.35

1.7

11.15

0.75

12.35

1.52

30.66

35.57

3.40

Conductor Specification

EPDM Insulation

LEAD Sheath

EPDM Shealth

Finished Size  mm

Calculated Weight kg/m

AWG

Area m㎡

Outer Diameter mm

Thickness mm

Outer Diameter mm

Thickness mm

Outer Diameter mm

Thickness mm

Outer Diameter mm

 

 

6

13

4.12

1.9

7.92

0.75

9.52

1.52

24.57

30.50

2.12

4

20

5.19

1.9

8.99

0.75

10.59

1.52

26.81

32.78

2.59

2

33

6.54

1.9

10.34

0.75

11.94

1.52

29.78

35.70

3.11

1

42

7.35

1.9

11.15

0.75

12.75

1.52

31.53

37.43

3.50

Get a sample