Underground Direct Burial Cable

Underground Direct Burial Cable

Underground Direct Burial Cables from the manufacturers at Holdone are ideal for building your reliable power and communications network. These high-performance cables are designed to be laid underground, providing you with superior performance and long-lasting durability. The use of state-of-the-art technology and materials ensures that they will perform well in a variety of harsh environments. And they transmit power efficiently, reducing energy loss while ensuring a stable supply and high-quality power transmission. It also has excellent signal transmission characteristics, ensuring high definition and low latency data transmission. Whether the application is in telephony, broadband networks or data centres, these cables can transmit data stably and meet your needs for high-speed, stable networks. Our Underground Direct Burial Cable meets the most stringent safety standards and has passed several certifications to ensure the safety and reliability of our products.

Underground Direct Burial Cable

SKU Words

Size AWG

Nominal Insulation (mils)

Approx. O.D. (inches)

Estimated Weight

lbs./1000 ft.

Ampacitivity Directly Buried

 

 

 

 

Aluminum

Total

 

NNC1895X

6

60

0.298

25

44

108

NNC1896X

4

60

0.345

39

63

140

NNC1897X

2

60

0.403

62

92

180

NNC1898X

1

80

0.473

78

121

203

NNC1899X

1/0

80

0.512

99

146

231

NNC1900X

2/0

80

0.555

125

177

263

NNC1901X

3/0

80

0.603

157

215

299

NNC1902X

4/0

80

0.658

198

263

338

NNC1903X

250

95

0.732

234

314

368

NNC1904X

300

95

0.784

281

367

407

NNC21477X

350

95

0.831

328

420

444

NNC1905X

400

95

0.875

376

476

475

NNC1906X

500

95

0.956

469

577

540

NNC1907X

600

110

1.060

562

697

595

NNC1908X

700

110

1.127

656

804

645

NNC21478X

750

110

1.159

703

853

667

NNC1909X

1000

110

1.304

937

1108

800

SKU Word

Phase Conductor

Neutra l

Single Phase Conductor (inches)

Outside Diameter (inches)

Weight (lbs. /1000ft.)

Ampacity

(Amps)

 

Size AWG

Strand

Insulation Thickness (mils)

Size AWG

Strand

Insulation Thickness (mils)

 

 

 

Direct Burial

In Duct

Bard

8

7/W

60

8

7/W

60

0.262

0.524

76

70

70

Claflin

6

7/W

60

6

7/W

60

0.299

0.596

91

95

70

Delgado

4

7/W

60

4

7/W

60

0.345

0.690

125

125

90

Everett

2

7/W

60

2

7/W

60

0.403

0.800

189

187

100

SKU Word

Phase Conductor

Neutra l

Single Phase Conductor (inches)

Outside Diameter (inches)

Weight (lbs. /1000ft.)

Ampacity

 

 

 

 

 

 

(Amps)

 

Size AWG

Strand

Insulation Thickness (mils)

Size AWG

Strand

Insulation Thickness (mils)

 

 

 

Direct Burial

In Duct

Erskine

6

7

60

6

7/W

60

0.299

0.646

143

95

70

Vassar

4

7

60

4

7/W

60

0.345

0.754

203

125

70

Stephens

2

7

60

4

7/W

60

0.403

0.842

264

165

120

Ramapo

2

7

60

2

7/W

60

0.403

0.874

294

165

120

Brenau 

1/0

19

80

2

7/W

60

0.522

1.064

408

215

160

Bergen

1/0

19

80

1/0

19/w

80

0.522

1.133

465

215

180

Converse

2/0

19

80

1

19/w

80

0.566

1.174

502

245

180

Hunter

2/0

19

80

2/0

19/w

80

0.566

1.228

560

245

180

Hollins

3/0

19

80

1/0

19/w

80

0.616

1.276

608

280

205

Sweetbriar

4/0

19

80

2/0

19/w

80

0.672

1.389

739

315

240

Monmouth

4/0

19

80

4/0

19/w

80

0.672

1.457

828

315

240

Pratt

250

37

95

3/0

19/w

80

0.748

1.538

893

345

265

Wesleyan

350

37

95

4/0

19/w

80

0.851

1.736

1166

415

320

Rider

500

37

95

350

37/w

95

0.979

2.035

1663

495

395

SKU Word

Phase Conductor

Neutra l

Outside Diameter (inches)

Weight (lbs. /1000ft.)

Ampacity

 

 

 

 

 

(Amps)

 

Size AWG

Strand

Insulation Thickness (mils)

Size AWG

Strand

Insulation Thickness (mils)

 

 

Direct Burial

In Duct

Tulsa

4

7/w

60

4

7/W

60

0.893

258

119

85

Dyke

2

7/w

60

4

7/W

60

0.938

346

153

115

Wittenburg

2

7/w

60

2

7/W

60

0.973

375

153

115

Notre Dame

1/0

19/w

80

2

7/W

60

1.188

541

198

150

Syracuse

2/0

19/w

80

1

19/w

80

1.316

664

225

170

Davidson

3/0

19/w

80

3/0

19/w

80

1.487

874

250

195

Wake Forest

4/0

19/w

80

2/0

19/w

80

1.56

979

290

225

Earlham

4/0

19/w

80

4/0

19/w

80

1.623

1066

290

225

Rust

250

37/w

95

3/0

19/w

80

1.76

1203

325

245

Slippery Rock

350

37/w

95

4/0

19/w

80

1.945

1544

385

305

Wofford

500

37/w

95

350

37/w

95

2.348

2174

467

420

Windham

750

61/w

110

500

37/w

95

2.85

3147

615

492