Underground Direct Burial Cable
Underground Direct Burial Cables from the manufacturers at Holdone are ideal for building your reliable power and communications network. These high-performance cables are designed to be laid underground, providing you with superior performance and long-lasting durability. The use of state-of-the-art technology and materials ensures that they will perform well in a variety of harsh environments. And they transmit power efficiently, reducing energy loss while ensuring a stable supply and high-quality power transmission. It also has excellent signal transmission characteristics, ensuring high definition and low latency data transmission. Whether the application is in telephony, broadband networks or data centres, these cables can transmit data stably and meet your needs for high-speed, stable networks. Our Underground Direct Burial Cable meets the most stringent safety standards and has passed several certifications to ensure the safety and reliability of our products.
Underground Direct Burial Cable
SKU Words | Size AWG | Nominal Insulation (mils) | Approx. O.D. (inches) | Estimated Weight lbs./1000 ft. | Ampacitivity Directly Buried | |
|
|
|
| Aluminum | Total |
|
NNC1895X | 6 | 60 | 0.298 | 25 | 44 | 108 |
NNC1896X | 4 | 60 | 0.345 | 39 | 63 | 140 |
NNC1897X | 2 | 60 | 0.403 | 62 | 92 | 180 |
NNC1898X | 1 | 80 | 0.473 | 78 | 121 | 203 |
NNC1899X | 1/0 | 80 | 0.512 | 99 | 146 | 231 |
NNC1900X | 2/0 | 80 | 0.555 | 125 | 177 | 263 |
NNC1901X | 3/0 | 80 | 0.603 | 157 | 215 | 299 |
NNC1902X | 4/0 | 80 | 0.658 | 198 | 263 | 338 |
NNC1903X | 250 | 95 | 0.732 | 234 | 314 | 368 |
NNC1904X | 300 | 95 | 0.784 | 281 | 367 | 407 |
NNC21477X | 350 | 95 | 0.831 | 328 | 420 | 444 |
NNC1905X | 400 | 95 | 0.875 | 376 | 476 | 475 |
NNC1906X | 500 | 95 | 0.956 | 469 | 577 | 540 |
NNC1907X | 600 | 110 | 1.060 | 562 | 697 | 595 |
NNC1908X | 700 | 110 | 1.127 | 656 | 804 | 645 |
NNC21478X | 750 | 110 | 1.159 | 703 | 853 | 667 |
NNC1909X | 1000 | 110 | 1.304 | 937 | 1108 | 800 |
SKU Word | Phase Conductor | Neutra l | Single Phase Conductor (inches) | Outside Diameter (inches) | Weight (lbs. /1000ft.) | Ampacity (Amps) | |||||
| Size AWG | Strand | Insulation Thickness (mils) | Size AWG | Strand | Insulation Thickness (mils) |
|
|
| Direct Burial | In Duct |
Bard | 8 | 7/W | 60 | 8 | 7/W | 60 | 0.262 | 0.524 | 76 | 70 | 70 |
Claflin | 6 | 7/W | 60 | 6 | 7/W | 60 | 0.299 | 0.596 | 91 | 95 | 70 |
Delgado | 4 | 7/W | 60 | 4 | 7/W | 60 | 0.345 | 0.690 | 125 | 125 | 90 |
Everett | 2 | 7/W | 60 | 2 | 7/W | 60 | 0.403 | 0.800 | 189 | 187 | 100 |
SKU Word | Phase Conductor | Neutra l | Single Phase Conductor (inches) | Outside Diameter (inches) | Weight (lbs. /1000ft.) | Ampacity | |||||
|
|
|
|
|
| (Amps) | |||||
| Size AWG | Strand | Insulation Thickness (mils) | Size AWG | Strand | Insulation Thickness (mils) |
|
|
| Direct Burial | In Duct |
Erskine | 6 | 7 | 60 | 6 | 7/W | 60 | 0.299 | 0.646 | 143 | 95 | 70 |
Vassar | 4 | 7 | 60 | 4 | 7/W | 60 | 0.345 | 0.754 | 203 | 125 | 70 |
Stephens | 2 | 7 | 60 | 4 | 7/W | 60 | 0.403 | 0.842 | 264 | 165 | 120 |
Ramapo | 2 | 7 | 60 | 2 | 7/W | 60 | 0.403 | 0.874 | 294 | 165 | 120 |
Brenau | 1/0 | 19 | 80 | 2 | 7/W | 60 | 0.522 | 1.064 | 408 | 215 | 160 |
Bergen | 1/0 | 19 | 80 | 1/0 | 19/w | 80 | 0.522 | 1.133 | 465 | 215 | 180 |
Converse | 2/0 | 19 | 80 | 1 | 19/w | 80 | 0.566 | 1.174 | 502 | 245 | 180 |
Hunter | 2/0 | 19 | 80 | 2/0 | 19/w | 80 | 0.566 | 1.228 | 560 | 245 | 180 |
Hollins | 3/0 | 19 | 80 | 1/0 | 19/w | 80 | 0.616 | 1.276 | 608 | 280 | 205 |
Sweetbriar | 4/0 | 19 | 80 | 2/0 | 19/w | 80 | 0.672 | 1.389 | 739 | 315 | 240 |
Monmouth | 4/0 | 19 | 80 | 4/0 | 19/w | 80 | 0.672 | 1.457 | 828 | 315 | 240 |
Pratt | 250 | 37 | 95 | 3/0 | 19/w | 80 | 0.748 | 1.538 | 893 | 345 | 265 |
Wesleyan | 350 | 37 | 95 | 4/0 | 19/w | 80 | 0.851 | 1.736 | 1166 | 415 | 320 |
Rider | 500 | 37 | 95 | 350 | 37/w | 95 | 0.979 | 2.035 | 1663 | 495 | 395 |
SKU Word | Phase Conductor | Neutra l | Outside Diameter (inches) | Weight (lbs. /1000ft.) | Ampacity | |||||
|
|
|
|
| (Amps) | |||||
| Size AWG | Strand | Insulation Thickness (mils) | Size AWG | Strand | Insulation Thickness (mils) |
|
| Direct Burial | In Duct |
Tulsa | 4 | 7/w | 60 | 4 | 7/W | 60 | 0.893 | 258 | 119 | 85 |
Dyke | 2 | 7/w | 60 | 4 | 7/W | 60 | 0.938 | 346 | 153 | 115 |
Wittenburg | 2 | 7/w | 60 | 2 | 7/W | 60 | 0.973 | 375 | 153 | 115 |
Notre Dame | 1/0 | 19/w | 80 | 2 | 7/W | 60 | 1.188 | 541 | 198 | 150 |
Syracuse | 2/0 | 19/w | 80 | 1 | 19/w | 80 | 1.316 | 664 | 225 | 170 |
Davidson | 3/0 | 19/w | 80 | 3/0 | 19/w | 80 | 1.487 | 874 | 250 | 195 |
Wake Forest | 4/0 | 19/w | 80 | 2/0 | 19/w | 80 | 1.56 | 979 | 290 | 225 |
Earlham | 4/0 | 19/w | 80 | 4/0 | 19/w | 80 | 1.623 | 1066 | 290 | 225 |
Rust | 250 | 37/w | 95 | 3/0 | 19/w | 80 | 1.76 | 1203 | 325 | 245 |
Slippery Rock | 350 | 37/w | 95 | 4/0 | 19/w | 80 | 1.945 | 1544 | 385 | 305 |
Wofford | 500 | 37/w | 95 | 350 | 37/w | 95 | 2.348 | 2174 | 467 | 420 |
Windham | 750 | 61/w | 110 | 500 | 37/w | 95 | 2.85 | 3147 | 615 | 492 |